SR-NIEL – 7

Screened Relativistic (SR) Treatment for NIEL Dose

Nuclear and Electronic Stopping Power Calculator

(version 10.14)

Proton High AMS02 small

This is the Non-Ionizing Energy-Loss (NIEL) Code Web application for neutrons not using ASTM Standard.

The following links give access to neutron NIEL code:

- Neutrons NIEL calculator (registered)

 

How to use this Neutron NIEL Calculator


This tool allows one to obtain the NIEL values and NIEL doses from some elements and compounds from values obtained using the software NJOY (2021 versions) developed by Los Alamos National Laboratory with the ENDF/B.VIII.0 cross section library.

The input parameters and options for the tool are described below. When the input form has been completed, pressing the "CALCULATE" button will start the calculation and open the "Results" page (allow for pop-up in your browser settings). The result page will also be linked at the bottom of the calculator page.

Input Parameters:

- Target material
- Calculator energy limits
- Particle fluence.

 

Target Material

In this section, it is possible to specify the target material by selecting 6 different common used semiconductors: Si, Ge, GaAs, SiC, GaN, InP, InGaP.

Experimentally determined Ed values:

  • Ga: 21.5 eV, As: 21.5 eV as reported in [Campesato et al. (2019)] from proton, electron and neutron irradiations of solar cells. In Triple Junction solor cells, in which the dominat damage mechanism is that one due to the GaAs middle junction, a commonly effective value of Ed was 24 eV [Campesato et al. (2018)], [Campesato et al. (2019)].
  • Ge: 40.5 eV as reported in [Campesato et al. (2019)].
  • In: 43 eV, Ga: 21 eV, P: 21 eV as reported in [Campesato et al. (2018)] for In0.49Ga0.51P single junction solar cells irradiated with electrons and protons. In [Campesato et al. (2019)] with electron, proton and neutron irradiation, it was shown that a commonly effective value of Ed=38 eV can be employed in an equivalent way.

 

Energy Limits

This section defines the energy limits of the calculation, and the following parameters will be defined:
- Minimum Energy of the incident particle
- Maximum Energy of the incident particle

 

Particle Fluence for Displacement Damage Dose Calculation

Here is defined the particle fluence that is used to obtain the deposited NIEL Dose (i.e., the displacement damage dose).

Result

The result page contains the input parameters, the NIEL curve and the result table, which includes the NIEL, and the NIEL Dose (in [MeV g-1] and [Gy])